UL 3644 High Voltage Silicone Lead Wire

Details
Rowe Industries "Super Tough" high voltage silicone wire for UL 3644 applications uses a compound specially developed for high abrasion resistant requirements and excellent dielectric capabilities in extreme environments. Our proprietary compound allows us to meet the stringent requirements of UL 3644 including a 1,000v rating and 150C or 200C degrees continuous.
  • Super Tough" insulation means that there is no need for “silly braid” embedded in the insulation jacket making it easier to process and strip, especially in high volume processes
  • Silicone insulation
  • 1000 Volts AC voltage rating
  • 200°C degrees continuous use rating
  • 22 AWG through 500MCM size conductors
  • High flexibility
  • Flame retardant, low smoke, zero halogen

18 AWG UL 3644, 1000V AC, 200C CSA AWM

4/0AWG | 1000V AC | UL 3644 | 200C | CSA AWM

1/0AWG | 1000V AC | UL 3644 | 200C | CSA AWM

4AWG | 1000V AC | UL 3644 | 200C | CSA AWM

10AWG | 1000V AC | UL 3644 | 200C | CSA AWM

16AWG | 1000V AC | UL 3644 | 200C | CSA AWM

2/0AWG | 1000V AC | UL 3644 | 200C | CSA AWM

2AWG | 1000V AC | UL 3644 | 200C | CSA AWM

8AWG | 1000V AC | UL 3644 | 200C | CSA AWM

14AWG | 1000V AC | UL 3644 | 200C | CSA AWM

3/0AWG | 1000V AC | UL 3644 | 200C | CSA AWM

1AWG | 1000V AC | UL 3644 | 200C | CSA AWM

6AWG | 1000V AC | UL 3644 | 200C | CSA AWM

12AWG | 1000V AC | UL 3644 | 200C | CSA AWM

Description

Features:

  • Super Tough" insulation means that there is no need for “silly braid” embedded in the insulation jacket making it easier to process and strip, especially in high volume processes
  • Silicone insulation
  • 1000 Volts AC voltage rating
  • 200°C degrees continuous use rating
  • 22 AWG through 500MCM size conductors
  • High flexibility
  • Flame retardant, low smoke, zero halogen

Applications:

Rowe's R800 Series High Voltage Silicone Lead Wire has been used in power supplies, electronic equipment, etc... where high abrasion resistance, high voltage, flame resistance, and flexibility are major requirements.

USE THE PRODUCT LIST BELOW TO SELECT. YOU CAN SORT BY GAUGE, VOLTAGE AND TEMPERATURE RATINGS

Part NumberAWG Size# StrandsMin. Avg. Wall InchesOD Inches Paper WrapCSA
UL3644-BHB- 18 7 0.035 0.121 No AWM I A/B FT-2
UL3644-BJB- 16 7 0.035 0.133 No AWM I A/B FT-2
UL3644-BKB- 14 7 0.035 0.147 No AWM I A/B FT-2
UL3644-BLE- 12 19 0.037 0.168 No AWM I A/B FT-2
UL3644-BMG- 10 37 0.045 0.205 No AWM I A/B FT-2 
UL3644-BN70- 8 70 0.060 0.313 Yes AWM I A/B FT-2 
UL3644-BP114- 6 114 0.060 0.362 Yes AWM I A/B FT-2 
UL3644-BRL- 4 133 0.060 0.392 Yes AWM I A/B FT-2 
UL3644-BSN- 2 259 0.060 0.462 Yes AWM I A/B FT-2 
UL3644-BTN- 1 259 0.080 0.540 Yes AWM I A/B FT-2 
UL3644-BUN- 1/0 259 0.080 0.590 Yes AWM I A/B FT-2 
UL3644-BWN- 2/0 259 0.080 0.645 Yes AWM I A/B FT-2 
UL3644-BYN- 3/0 259 0.080 0.705 Yes AWM I A/B FT-2 
UL3644-BZN- 4/0 259 0.080 0.765 Yes AWM I A/B FT-2