For every equipment, appliance and fixture design, there is one or more Flexlead constructions that will efficiently and economically provide the required performance in-use.  Below are two listings: One, numerically by the applicable style number or alphabetic identification system used by the controlling agency; Two, wherein materials are compiled relative to end-use, temperature and voltage parameters.  Flexlead styles will be added as applicable.  Please contact us for the most current approval status.
 
LISTED BY STYLE NUMBER
 
U.L.
Style
Insulation Size Range Wall Thickness Rating Jacket
3075 Silicone Rubber #10 3/64" 200°C 600V Fiberglass
3079 Silicone Rubber .0015 1/32" 150°C 300V Fiberglass
3081 Silicone Rubber .0015 1/32" 150°C 600V  
3083 Silicone Rubber .0015 4/64" 150°C 300V  
3099 Silicone Rubber #20-#16 1/32" 150°C 300V  
3101 Silicone Rubber #10 3/64" 150°C 600V Fiberglass
3114 Silicone Rubber .0015 4/64" 150°C 600V  
3115 Silicone Rubber #20 1/32" 150°C 300V  
3123 Silicone Rubber #24-#16 1/32" 150°C 600V  
3125 Silicone Rubber #8-#2 1/16" 200°C 600V Fiberglass
3126 Silicone Rubber #1-4/0 5/64" 200°C 600V Fiberglass
3127 Silicone Rubber #8-#2 1/16" 150°C 600V Fiberglass
3128 Silicone Rubber #1-4/0 5/64" 150°C 600V Fiberglass
3129 Silicone Rubber .0015 3/64" 150°C 300V  
3130 Silicone Rubber .0015 3/64" 150°C 300V  
3133 Silicone Rubber #24-#16 1/32" 150°C 600V  
3134 Silicone Rubber #18-#22 1/32" 150°C 600V  
3135 Silicone Rubber #24-#12 1/32" 200°C 600V  
3136 Silicone Rubber #24-#20 3/64" 150°C 300V  
3137 Silicone Rubber #24-#20 3/64" 150°C 600V  
3138 Silicone Rubber #18-#9 .045 150°C 600V  
3139 Silicone Rubber #24-#12 .045 200°C 600V  
3140 Silicone Rubber #24-#20 1/16" 150°C 300V  
3141 Silicone Rubber #24-#20 1/16" 150°C 600V  
3142 Silicone Rubber #18-#12 1/16" 150°C 600V  
3143 Silicone Rubber #18-#12 1/16" 200°C 600V  
3148 Silicone Rubber .0015 3/64" 150°C 300V Fiberglass
3149 Silicone Rubber .0015 1/16" 150°C 300V Fiberglass
3150 Silicone Rubber .0015 1/32" 150°C 300V  
3151 Silicone Rubber .0015 3/64" 150°C 300V  
3152 Silicone Rubber .0015 3/64" 150°C 300V  
3153 Silicone Rubber .0015 1/16" 150°C 300V Fiberglass
3161 Silicone Rubber .0015 1/32" 150°C 300V Fiberglass
3171 Silicone Rubber #22-#12 1/32" 150°C 600V  
3177 Silicone Rubber Special 1/32" 150°C 300V  
3178 Silicone Rubber Special 4/64" 150°C 300V  
3179 Silicone Rubber Special 3/64" 150°C 300V  
3211 Silicone Rubber #24-#14 1/32" 150°C 300V  
3212 Silicone Rubber #24-#10 3/64" 150°C 600V  
3213 Silicone Rubber #8-#2 4/64" 150°C 600V  
3214 Silicone Rubber #1-4/0 5/64" 150°C 600V  
3215 Silicone Rubber #18-#16 4/64" 150°C 600V  
3216 Silicone Rubber #14,#12,#10 5/64" 150°C 600V  
3219 Silicone Rubber .0015 1/32" 150°C 300V  
3222 Silicone Rubber .0015 3/64" 150°C 300V  
3223 Silicone Rubber .0015 4/64" 150°C 300V  
3224 Silicone Rubber #28+ 1/32" 150°C 300V  
3231 Silicone Rubber #8-4/0 4/64"-5/64" 200°C 600V Fiberglass
3239 Silicone Rubber #24-#10 See Data 150°C - 50 KVDC  
3243 Silicone Rubber #24-#16 4/64" 150°C 300V  
3251 Silicone Rubber #24-10 .045" 250°C 600V  
3253 Silicone Rubber #24-#12 .030" 250°C 300V  
3256 Silicone Rubber #22-#12 .078" 250°C 10 KVRMS  
3257 Silicone Rubber #22-#12 .078" 250°C 10 KVAC  
3260 Silicone Rubber #22-#12 .031" 230°C 300V  
3261 Silicone Rubber #22-#12 .078" 230°C 10 KVRMS  
3262 Silicone Rubber #24-#20 1/32" 200°C 600V  
3267 Silicone Rubber Special 6/64" 150°C 600V  
3268 Silicone Rubber #18-#12 1/32" 200°C 600V  
3274 Silicone Rubber #20 .050" 150°C 10 KVRMS Special
3278 Silicone Rubber #8-4/0 4/64"-5/64" 150°C 600V Fiberglass
3301 Silicone Rubber #20-4/0 .040"-.090" 150°C 600V Fiberglass
3305 Silicone Rubber .0015 .020" 150°C 300V Fiberglass (opt)
3316 Silicone Rubber .001 1/32" 200°C 300V Fiberglass
3322 Silicone Rubber #24-#16 .030" 200°C 600V  
3326 Silicone Rubber #24-#10 .062" 150°C 10 KVAC  
3333 Silicone Rubber #22-#12 .030" 230°C 10 KV Special
3342 Silicone Rubber .001" .016" 200°C 300V  
3350 Silicone Rubber .0015 .015" 200°C 600V  
3353 Silicone Rubber .0015 1/32" 200°C 600V  
3365 Silicone Rubber #24-#10 .070" 150°C 10 KVAC  
3407 Silicone Rubber .001-.011 .030" 200°C 300V  
3520 Silicone Rubber #18-#10 3/64" 150°C 600V  
CSA SR-INSULATED EQUIPMENT WIRES
 
Style Insulation Size Range Wall Thickness Rating Jacket
CSA Silicone Rubber #24-500 KCML 43 Mils 150°C 600V  
 
APPLIANCE WIRING CONDUCTORS
In most instances, appliance wiring conductors are constructed of solid or stranded copper, nickel, or special alloys.  When copper is used, it is usually required to have a coating of tin, silver, or nickel, either cladded or plated.  For 150C rated constructions, individual wires within the conductor normally shall not be smaller than #24 AWG, except solid conductors and some business machine wires which are defined by the applicable style requirements.  200C wires require strands no smaller than #24 AWG.  Unless special requirements exist, Rowe Industries, Inc. supplies tinned copper conductor in labeled constructions.

FIXTURE & EQUIPMENT WIRING CONDUCTORS
Fixtures and equipment wiring conductors are constructed of either solid or stranded nickel or copper.  When copper is used, it shall have a coating of tin, silver, or nickel, with individual wires within stranded conductors to be #26 to #36 AWG inclusive.  Unless special requirements exist, Rowe Industries supplies tinned copper conductor in labeled construction.

JACKETING
When required, Rowe Industries supplies a fiberglass overbraid with a heat, flame and moisture resistant saturant in accordance with commercial and military specifications.

SPECIAL CONSIDERATIONS
All constructions described in this brochure are available with labels indicating their listing as recognized wiring materials by Underwriters' Laboratories and Canadian Standards Association and as such incorporate all necessary markers, jackets, stripes, etc., to conform to applicable style requirements.  Where these labels are not required, Rowe Industries can supply these configurations or similar cables in custom materials designed to meet your exacting requirements.

NOTES
Technical requirements and design technology are constantly changing to meet the needs of industry both today and in the future.  If your required style is not listed, or design requirements dictate specially manufactured items, please call us and let us assist you in determining the best construction for your application, or fill out our custom quote form.  Chances are you may be pleasantly surprised to discover that we have a material ideally suited to your needs.  Since Approval Agencies' requirements are subject to periodic review and revision, constructions and data given herein are for information only.  Contact factory for current specifications.  Underwriter's File #E-61355 CSA File #LL103756.


 
 





















Copyright 2005 D&B Industrial Group
This site created by InterNetworking Technologies
Contact the Webmaster Scott Livingood


Visit our other sites:
Dielectric Insulation (Spiral Wound Tubing) http://www.dielectricinsulation.com - PrimeWeld (Thermoplastic Welding Rods) http://www.primeweld.net
Thermoplastic Processes (Thermoplastic Pipe, Tubing, Rods) http://www.excelon.com - ER Tape (Emergency Repair Tape) http://www.ertape.com
DB Industrial Group (Corporate Website) http://www.dbindustrialgroup.com